Illustration of refinery pipework, vessels and process equipment

Oil & gas · Construction & pre-commissioning

Chemicals for oil & gas pre-commissioning.

Clean pipework and vessels, treat pressure-test water and protect equipment while it waits to enter service.

From fabrication to first fill

Find the treatment for
the task ahead.

For commissioning contractors, fabricators, EPC teams and plant owners preparing refinery pipework, vessels and utility equipment. Choose the relevant duty below; the project’s cleaning and commissioning procedure determines which treatments are needed and in what order.

Illustrative equipment for Cleaning & degreasing
01

Remove fabrication oils

Cleaning & degreasing

Clean oily residues from new pipework, vessels and boiler water-side surfaces before the next treatment or startup.

  • X-Pro Degreaser NC LF

    Low-foam circulation cleaning of fabrication oils and grease with fresh water.

  • X-Pro BoilClean AL

    Alkaline cleaning of oily carbon-steel boiler water-side surfaces, with sodium sulfite for oxygen control during cleaning.

Illustrative equipment for Rust & mineral deposits
02

Match the cleaner to the deposit

Rust & mineral deposits

Iron rust, mill scale and water-side mineral deposits need different cleaning approaches.

  • X-Pro RustBreak

    Inhibited acid cleaning of rust and mill scale on ordinary, uncoated carbon steel.

  • X-Pro RustBreak Multi

    Controlled immersion cleaning of iron rust on ordinary-steel parts and deposited iron staining on specified metals; confirm the metal and finish.

  • X-Pro ScaleBreak

    Carbonate-rich mineral scale on acid-compatible water-side equipment, including reused equipment returning to service.

Illustrative equipment for Pickling & passivation
03

Prepare stainless-steel surfaces

Pickling & passivation

Remove weld-related oxides where necessary, then address surface iron contamination on prepared 304 and 316L stainless steel.

  • X-Pro Pickle SS

    Specialist nitric/HF pickling for weld heat tint and oxide scale on prepared 304/316L stainless steel, with the required HF handling and gas controls.

  • X-Pro Passivate SS

    Citric-acid passivation for surface iron contamination on prepared 304/316L stainless steel; not a heat-tint remover.

Illustrative equipment for Hydrotest water treatment
04

Treat the water used for pressure testing

Hydrotest water treatment

Select corrosion control, oxygen removal and microbiological treatment for the test-water conditions and holding period.

  • X-Pro HydroTest CI Multi

    Corrosion-inhibitor treatment for fresh-water hydrotesting and specified closed wet holding; check every wetted metal, including aluminium.

  • X-Pro OxyScav HT

    Oxygen removal and corrosion inhibition for fresh-water hydrotesting and specified closed wet holding of carbon-steel equipment.

  • X-Pro HydroBio HT

    Initial bacterial-control treatment for fresh-water hydrotesting of carbon-steel equipment; holding-period control needs its own treatment plan.

Illustrative equipment for Passivation & preservation
05

Protect equipment between stages

Passivation & preservation

After cleaning or testing, match the protection method to the metal, the equipment condition and the wait before service.

  • X-Pro Passivate CS

    Passivation of cleaned, rinsed carbon-steel auxiliary pipework and vessels; excludes boilers, steam systems and mixed metals.

  • X-Pro PreserveGuard

    Temporary protection of cleaned, drained and enclosed ordinary carbon-steel equipment; not water-filled or open outdoor storage.

Illustrative equipment for Utility & cleaning water
06

Prepare utility water and manage used water

Utility & cleaning water

Select clarification, chlorination or chlorine removal for the particular duty. Water analysis and receiving-system or discharge requirements determine the treatment needed.

  • X-Pro Coagulate WT

    Coagulation of fine suspended solids in utility-water clarification; not complete treatment of oily or chemically contaminated cleaning waste.

  • X-Pro Floc WT

    Flocculation of suspended solids for settling or separation in a suitable water-treatment process.

  • X-Pro Chlorinate WT

    Chlorination of cleaned, isolated non-potable industrial tanks and pipework during commissioning.

  • X-Pro Dechlor WT

    Free-chlorine removal after the required contact period, where dechlorination is needed. Treatment alone does not establish discharge suitability.

Product selection starts with the equipment.

Confirm product suitability for the specific metals, surface finishes, water and operating conditions before supply. Product pages explain the chemistry and important limits. Combining treatments requires a compatible, agreed procedure.

Supporting the cleaning programme

Rinsing and the move
into operation.

Controlled alkaline rinsing

X-Pro Caustic 50 supports separately controlled dilute alkaline rinsing of ordinary carbon steel after acid cleaning, once the acid has been drained and the initial water rinse completed. It is not a complete inhibited cleaning blend.

Closed cooling circuits at first fill

X-Pro CoolingGuard CL and X-Pro CoolingGuard Multi cover corrosion control from the first fill of a cleaned, water-only closed cooling circuit and during operation. Choose the grade for the metals present and define the changeover from test or holding water.

Common project questions

Choose with the next
stage in mind.

Do we need every product listed?

No. The equipment materials, contamination, test-water conditions and time before startup determine the treatments required. These are product options for different duties, not a compulsory sequence.

Can one cleaner cover carbon steel and stainless steel?

Do not assume so. Carbon-steel rust removal, stainless-steel heat-tint removal and passivation are different tasks. Choose the product for the specific metal, deposit and surface finish.

Can hydrotest treatments be mixed together?

Not automatically. Some products already combine functions. Confirm chemical compatibility and the treatment programme before combining a corrosion inhibitor, oxygen scavenger or biocide.

What information should I send for a quotation?

Start with the cleaning or treatment task, equipment material, approximate system volume or product quantity, site location and required timing. Include water-test results or project requirements if you already have them.

X-Pro · Nairobi, Kenya

Tell us what you need
to clean, test or protect.