Bacterial control for hydrotest water
X-Pro HydroBio HT is a liquid biocide concentrate for initial bacterial control in freshwater used to pressure-test carbon-steel pipes, vessels and equipment. Its dose and contact time are specified for the microbial treatment required, separately from any oxygen-scavenger or corrosion-inhibitor dose.
Industries: Oil & gas / refineries; Engineering & fabrication; Chemical manufacturing; Power & utilities.
Application requirements: Use the specified dose, mixing and contact time for the hydrotest water. Check bacterial response and biocide residual; specify wet holding separately.
Key ingredient
Tetrakis(hydroxymethyl)phosphonium sulfate (THPS). THPS is a nonoxidising biocide for controlling bacteria in the test water. Oxygen removal and corrosion inhibition must be specified separately where needed.
Applications
- Treating freshwater used to fill cleaned carbon-steel pipework for pressure testing.
- Initial bacterial treatment of water for pressure-testing fabricated vessels and process equipment.
- Treating replacement freshwater before pressure testing resumes.
Prepare the equipment and control the treatment
Clean and flush the equipment to remove oil, loose deposits and debris before treatment. A biocide does not replace physical cleaning.
The treatment procedure must provide effective mixing and the specified contact time. Check bacterial response and the biocide residual using methods suitable for the water and other chemicals present. A residual reading alone does not establish bacterial control.
Materials and use limits
Use this grade only for freshwater hydrotests of carbon-steel equipment under the specified treatment conditions. Include seals, coatings, valves and other wetted components when assessing suitability.
Do not use on other metals or with seawater, brines or glycol mixtures. Do not use for drinking-water treatment, public-health disinfection or routine cooling-water treatment. It is not a treatment for dry headspaces or equipment after draining.
Follow the specified collection, treatment and disposal procedure for used water. Do not assume biocide-treated water is suitable for discharge.
Pack sizes
5 L, 20 L and 200 L.
Manufacturing and application support
X-Pro draws on industrial chemical formulation and manufacturing experience to match microbial treatment to your hydrotest. Application support covers water conditions, treatment delivery, contact time and monitoring.
Frequently asked questions
Can it be used with OxyScav HT or HydroTest CI Multi?
Do not combine them automatically. X-Pro OxyScav HT addresses oxygen removal and corrosion inhibition; X-Pro HydroTest CI Multi follows a separate corrosion-inhibitor route. Their treatment doses do not establish microbial control. The complete programme and dosing sequence must be checked because scavengers and other chemicals can affect biocide activity. Separate addition alone does not establish compatibility. Do not mix concentrates.
Can equipment remain filled after the pressure test?
Wet holding needs a separately specified programme. Initial bacterial treatment does not establish continuing protection: the holding period needs confirmed persistence, monitoring and compatibility with the other treatments.
How much should be added?
Dose and contact time depend on the water volume, microbial condition, temperature and treatment delivery. Use the specified procedure and measured response; a fixed dose or pack size cannot establish effective treatment.
Request a quote
Tell us your preferred pack size and quantity.